The following references can be using during the General Building Inspector exam:
The 2021 IBC® contains many important changes such as:
- Puzzle rooms (escape rooms) are now defined and regulated as special amusement areas, requiring compliance with Section 411 and special means of egress requirements.
- For the purposes of determining the allowable number of control areas in a building, each portion separated by one or more fire walls is now considered as a separate building.
- In Group E occupancies, enhanced classroom acoustics in compliance with ICC A117.1 are to be provided in all classrooms having of volume of 20,000 cubic feet or less.
- The requirements for metal composite materials and systems (MCM) installed on the exterior walls of Types I, II, III and IV construction were simplified and sprinkler allowances were deleted.
- The use of intermodal shipping containers as buildings is now specifically addressed through provisions intended to supplement existing applicable IBC requirements.
- Automatic sprinkler protection is now required in Group S-2 open parking garages where any fire area exceeds 48,000 square feet.
- The 2017 edition of ICC A117.1 was adopted.
- Parapets of a minimum height are now required for aggregate-surfaced roofs to prevent blow-off.
- Mixed occupancy buildings with assembly spaces are placed in Risk Category III when the total public assembly occupant load is greater than 2500 people.
- The 2021 IBC snow map is updated to match ASCE 7-16 snow maps by adding a reference to ASCE 7 snow tables in states with large case study areas.
- Secondary rain loads are updated to be consistent with ASCE 7.
- Special inspection requirements were added to address the anchorage and connection of mass timber structural elements.
- Installation of firestop, fire-resistant joint systems and perimeter fire barrier systems in residential-use buildings now requires special inspection in Group R fire areas having an occupant load exceeding 250 people.
- Frost protection for egress doors was added to the foundation requirements.
- ACI standards ACI 117 and ITG 7 were added by reference to provide acceptable tolerances for concrete construction.
- Three new types of construction (Types IV-A, IV-B, and IV-C) allow mass timber buildings of taller heights, more stories above grade, and greater allowable areas compared to existing provisions for heavy timber buildings.
The 2021 IRC® contains many important changes such as:
- Braced wall lines must be placed on a physical wall or placed between multiple walls.
- The rated separation for two-family dwellings is 1 hour whether or not a lot line exists between units.
- Emergency escape and rescue openings require a clear 36-inch-wide path to a public way.
- An engineered design is required for storm shelters.
- A habitable attic is limited to one-half the area of the story below and the dwelling requires sprinklers.
- Updated Wind Speed maps match IBC and ASCE 7 maps.
- Deck design now considers snow load, tributary area for footing and post height, and guard details.
- Specific requirements for deck guardrails were added.
- Component and cladding wind pressures in Table R301.2(2) are updated for new design wind speeds and hip or gable roof profiles.
- Minimum footing size tables are revised to more accurately reflect current practice.
- Cripple wall requirements apply only to exterior cripple walls.
- New appendices for cob construction and 3D printed construction are added.
- A 30 percent reduction of airflow is permitted for balanced ventilation systems.
- Commercial gas cooking appliances are prohibited.
- The head pressure for a water test of DWV systems increased to 10 feet.
- Air vacuum testing is now permitted for plastic piping DWV systems.
- Section P2904 for dwelling sprinklers is expanded to more closely align with NFPA 13D.
- An emergency service disconnect is required in a readily accessible outdoor location.
- A surge-protective device (SPD) is now required at the service panel.
- The number of receptacle outlets required for peninsular and island countertops in kitchens is determined by the area of the countertop surface.
- GFCI protection is now required for damp and wet locations not included in the other 10 areas requiring GFCI protection.
Print for Your Exam:
New Mexico Residential Building Code (NMAC 14.7.3),2021
New Mexico Commercial Building Code (NMAC 14.7.2),2021
Pre-printed or blank tabs are also available.
Custom Tab Bundle, please specify which books these tabs should reference at checkout
The following references can be using during the Residential Inspector exam:
The 2021 IRC® contains many important changes such as:
- Braced wall lines must be placed on a physical wall or placed between multiple walls.
- The rated separation for two-family dwellings is 1 hour whether or not a lot line exists between units.
- Emergency escape and rescue openings require a clear 36-inch-wide path to a public way.
- An engineered design is required for storm shelters.
- A habitable attic is limited to one-half the area of the story below and the dwelling requires sprinklers.
- Updated Wind Speed maps match IBC and ASCE 7 maps.
- Deck design now considers snow load, tributary area for footing and post height, and guard details.
- Specific requirements for deck guardrails were added.
- Component and cladding wind pressures in Table R301.2(2) are updated for new design wind speeds and hip or gable roof profiles.
- Minimum footing size tables are revised to more accurately reflect current practice.
- Cripple wall requirements apply only to exterior cripple walls.
- New appendices for cob construction and 3D printed construction are added.
- A 30 percent reduction of airflow is permitted for balanced ventilation systems.
- Commercial gas cooking appliances are prohibited.
- The head pressure for a water test of DWV systems increased to 10 feet.
- Air vacuum testing is now permitted for plastic piping DWV systems.
- Section P2904 for dwelling sprinklers is expanded to more closely align with NFPA 13D.
- An emergency service disconnect is required in a readily accessible outdoor location.
- A surge-protective device (SPD) is now required at the service panel.
- The number of receptacle outlets required for peninsular and island countertops in kitchens is determined by the area of the countertop surface.
- GFCI protection is now required for damp and wet locations not included in the other 10 areas requiring GFCI protection.
Print for Your Exam:
New Mexico Residential Building Code (NMAC 14.7.3),2021
New Mexico Commercial Building Code (NMAC 14.7.2),2021
Pre-printed or blank tabs are also available.
Custom Tab Bundle, please specify which books these tabs should reference at checkout
Exam prep, books, and tabs for the Business & Law Exam:
Includes the following courses:
- New Mexico Business and Law Online Exam Prep
Plus the following:
- All the books to use during the exam
- Permanent/Pre-Printed Tabs
- Free Shipping!
- Instructor Support
- No Pass No Pay Policy
- Lifetime Access from nearly any device
New Mexico Business and Law Exam Bundle
New Mexico Business and Law Online Exam Prep
See Details
Included in the bundle
Lifetime Online Access to:
- New Mexico Business and Law Online Exam Prep
Our Online Exam Prep features:
Ideal for students who already own all references
NASCLA Contractors Guide to Business, Law and Project Management, Basic Edition
See Details
The NASCLA Contractors Guide to Business, Law and Project Management is organized into three sections.
Part 1 focuses on planning and starting your business. This section will help you formulate a business plan, choose a business structure, understand licensing and insurance requirements and gain basic management and marketing skills.
Part 2 covers fundamentals you will need to know in order to operate a successful construction business. This section covers estimating, contract management, scheduling, project management, safety and environmental responsibilities, and building good relationships with employees, subcontractors, and customers.
Part 3 provides valuable information to assist you in running the administrative functions of your business. Financial management, tax basics, and lien laws are covered. Effective management of these areas of business is vital and can cause you serious problems if you do not give them proper attention.
Print for Your Exam:
New Mexico Construction Industries Licensing Act (NMSA Chapter 60, Article 13)
New Mexico Contractor's License Requirement (NMAC Title 14, Chapter 6, Part 3)
Pre-printed or blank tabs are also available.
Custom Tab Bundle, please specify which books these tabs should reference at checkout
At RocketCert, we strive to be the best (while having fun in the process). This means having not only the best quality of education, but also industry leading technology. Best yet, we are here for you 7 days a week. Have a question or comment? Give us a call or contact us to send us a message. Ready to begin? Select from the training below and start immediately. Of course, you can resume later!
LIFETIME ACCESS
Why pay for something knowing your time with it is limited? At RocketCert, we believe in offering lifetime access to your training, even though it will not be needed.
EXPERT EDUCATION
Our education is written by industry experts. We believe in helping you with your career, and that help begins with offering best in class education.
CUSTOMER SUPPORT
We are here for you. Have a question? Need support? Our team is available 7 days a week for technical support. We pride ourselves in taking care of you.
EASY TO TAKE
Our training is available 24/7, and you can start and stop as needed. With our mobile ready courses, you can take from nearly any device at any location.