Key changes include:
- Log homes designed in accordance with the standard ICC 400, Standards on the Design and Construction of Log Structures, are exempt from the building thermal envelope requirements of the IECC.
- The maximum allowable fenestration U-factors in Table R402.1.2 (for the prescriptive compliance path) for climates zones 3 through 8 have been reduced from the values in the 2015 edition.
- The ICC/RESNET 380 standard has been included as one of standards that can be used for determining the air leakage rate of a building or dwelling unit.
- The Energy Rating Index compliance alternative index values have been increased slightly however, the method for determining an index is now required to be in accordance with standard ICC/RESNET 301.
- Revisions to interior and exterior lighting power budgets and better clarity for lighting controls.
- Clarity that regardless of design methodology, system commissioning is required.
- New limits on heated or cooled vestibules.
- Mechanical provisions reorganized based on equipment type rather than design methodology.